Q & A
A: Telide excels in high-pressure fluid control and applies its experience to valve test benches.
A: Nitrogen 600 MPa. Hydrogen 300 MPa. Liquid 700 MPa.
A: Neither gold nor silver prize is as valuable as the customer's praise. Welcome to research specific users.
A: Telide focuses on the high pressure field and has a stable technical team with over 20 years of experience.
A: What our customers say: Rest assured at critical moments.
Telide products can help customers quickly recoup their investments and generate long-term returns.
A: By the upper and lower ends of the piston area is poor, and get the high pressure fluid output, piston-driven gas side is a low pressure area, another liquid piston due to its small size, and high pressure.
A: Maximum output pressure is 67,860 PSI (4680bar).
A: Pump wetted parts material suitable for most liquids. Very minor changes to the pumps can be used solvents, deionized water and oil and skydrol.
A: Replace the manual pump, automatically and precisely, saving time and significantly superior.
A: Unlike electric pumps, Telide pumps are air-driven and are free of electrical arcs and sparks, making them safe for use in hazardous areas and confined spaces.
A: Industrial applications include charging accumulators, pressure-filled tire, filled shock absorber bracket, gas from one cylinder to another storage container, or in the machine tool for pneumatic clamps, for industrial machinery or test equipment of high-pressure gas in place. Gas drive air pump or air pump to provide special forces. Gas drive air pump output 10,000psi (690bar) high pressure gas.
A: Product design and safety factor of not less than 2:1.
A: A full range of high pressure VFT products. Pressure up to 1000MPa, size up to 1-1/2”, stable performance, moderate price.
A: Maximum output pressure is 4,000bar.
A: There is no need for high pressure valves, relief valves, etc., controlling high pressure with low pressure.
A: Yes, using low pressure hydraulic drive of the system itself.
After-sales service
Tel:+0086 755 3361 1128
E-mail:sales@telide.com.cn
Assist to install and adjust the equipment through the internet for you.
Provide technical training instructions till you can operate skillfully.
One year warranty for the complete equipments.
Maintenance: We can exchange parts and provide service for free during the guarantee period timely and effectively when there are problems .Once get the problems, our engineers will make a solution to help resolve them in the shortest time.
Technical Article
Elevated Temperature Usage
The following graph is for use with the Nova range of 316 stainless steel fittings and tubing. The thick line depicts the reduction in yield stress of the 316 and the corresponding reduction in valve rated pressure (some items may be used in the area above the line – consult agent or factory for specific cases).
The graph should be used for reference only as other considerations such as fatigue, creep, corrosion etc can affect performance at elevated temperatures. Please consult agent or factory for unusual operating conditions.
Standard Materials of Construction
Fittings (10,20,30,000 psi) | AISI 316 L/DIN 1.4404 to NACE MR-01-75 |
Fittings (60,000 psi/4000 bar/100,000 psi/7000 bar) | AISI 316 L/DIN 1.4404 |
Tubing (20, 30,000 psi) | AISI 316 L/DIN 1.4404 to NACE MR-01-75 |
Tubing (10, 20, 60,000 psi/4000 bar/100,000 psi/7000 bar) | AISI 316 L/DIN 1.4404 |
Filters (4000 bar) | AISI 316 L/DIN 1.4404 |
SPAREs KITS
To order spares kits, insert SK- in front of the valve catalogue number (see examples below).
To order individual connection components, use the catalogue numbers in the Fittings section.
To order any other individual components, contact factory or local agent.
LIQUID FLOW COEFFICIENTS KV IN M3/H
Kv values according to DIN EN 60543-2-3 for flow of water.
kv: flow of water in m3/h, temperature 5 to 30°C at a pressure drop of 1 bar (14.5 psi), in a determined direction through an object. Instruments in fully open position.
FLOW THROUGH CHECK VALVES AT VARIOUS PRESSURE
Note: Due to our policy of continuos development we reserve the right to modify products and specifications without notice.
Download
Video
BC-03 DIGITAL BUBBLE COUNTER
视频播放失败,请联系站点管理员!
BC-03 DIGITAL BUBBLE COUNTER
视频播放失败,请联系站点管理员!
BC-03 DIGITAL BUBBLE COUNTER
视频播放失败,请联系站点管理员!